EL LAMP
1. TYPICAL EL SPECIFICATIONS
| Normal Operating Voltage |
110Vac |
| Normal Operating Frequency |
400Hz |
| Max. Operating Voltage |
140Vac |
| Max. Voltage Allowed |
220Vac |
| Operating Current |
110Vac,
400Hz
|
< 0.14mA/cm2 |
| Capacitance |
<0.14nF/cm2 |
| Insulated Resistance |
> 20M Ohm |
| Max. Operating Frequency |
1500Hz |
| Max. Frequency Allowed |
5000Hz |
| Luminance (cd/m2) |
110Vac, 400Hz |
Green |
Bluish Green |
Blue |
55-65 |
55-65 |
28-34 |
| Chromaticity |
X |
0.19-0.20 |
0.18-0.19 |
0.16-0.17 |
Y |
0.47-0.48 |
0.40-0.42 |
0.20-0.22 |
| Operating Temperature |
-30 -
60oC |
| Storage Temperature |
-50 -
80oC |
| Max. Size |
40 x
60 cm2 |
| Min Size |
1 x 1
cm2 |
| Normal Thickness |
0.5mm |
| Min. Thickness |
0.2mm |
| Normal Sealed Size |
1.5mm |
| Min Sealed Size |
1mm |
| Min. Bend Radius |
38.1mm |
2. EL TYPICAL LIFE TIME (TEST VOLTAGE: 110Vac, 400Hz)
| Item |
Conditions |
Color |
Expected Life Time (Hour) |
| Room Condition |
20oC, 65% RH, Semi-luminance
fading conditions |
Green/Bluish Green |
>1000 |
|
Blue |
>300 |
| High Temperature and High Humidity |
40oC, 90% RH, Semi-luminance
fading conditions |
Green/Bluish Green |
>300 |
|
Blue |
>100 |
| High Temperature Storage |
70oC, Brightness not less than 75% of
the initial brightness |
- |
>1000 |
| Low Temperature Storage |
-30oC, Brightness not less than 75% of
the initial brightness |
- |
>1000 |
| High Temperature and High Humidity Storage |
40oC, 90% RH, Brightness not less than
40% of the initial brightness |
- |
>1000 |
Custom-Design